SIP Panel Dimensions

SIP panels: min/max dimensions in mm
Width 200mm (min) - 1220mm (max)
Length 6250mm (max)

SIP Panel Weights

SIP panels: weights in kg/sqm
Depth SIP type Weight
100mm Standard Internal Wall Partition 18kg/sqm
125mm Standard External Wall Panel 19kg/sqm
150mm External Wall / Roof Panel 20kg/sqm
175mm External Wall / Roof Panel 21kg/sqm

SIP Panel Thickness

SIP panels: thickness
Depth/Thickness OSB Polyurethane insulation core
100mm 2 x 12mm OSB 76mm rigid Polyurethane insulation core
125mm 2 x 12mm OSB 101mm rigid Polyurethane insulation core
150mm 2 x 12mm OSB 126mm rigid Polyurethane insulation core
175mm 2 x 12mm OSB 151mm rigid Polyurethane insulation core

Thermal Performance

The Core

The core of Build It Green Structural Insulated Panels is a high performance CFC/HCFC-free rigid urethane insulant of a typical density 33kg/m3.

CFC/HCFC-Free

Build It Green Structural Insulated Panels are manufactured without the use of CFC/HCFCs and have zero Ozone Depletion Potential (ODP).

Thermal Conductivity

Calculations of the thermal transmittance of specific constructions should be based on the thermal conductivity values (Wm-1 K-1) of their materials. These are:

SIP panels: Thermal conductivity values
Material Thermal conductivity values (Wm-1 K-1)
Polyurethane insulation core 0.025 (Wm-1 K-1)
OSB/3 0.13 (Wm-1 K-1)

Typical U-values

A U-value is a measure of heat loss. It is expressed in (W/m2k), and shows the amount of heat lost in watts (W) per square metre of material, when the temperature (k) is one degree lower outside. The lower the U-value, the better the insulation provided by the material.

The typical U-values for building elements is calculated in accordance with BS EN ISO 6946:1997 and BRE report (BR443:2006), and are shown in the table below:

SIP panels: typical U-values
Panel Thickness U-value (W/m2k)
100mm 0.27
125mm 0.21
150mm 0.17
175mm 0.14

Subject to the composition of the wall or roof section, extremely low U-values can be achieved between 0.1 (W/m2k) and 0.23 (W/m2k).

These U-values are much lower than those of standard construction techniques, demonstrating that SIP panels will insulate your property more efficiently to reduce heat loss.

Next: Fire performance and structural performance